ISO 7886-2-2020 pdf free download.Sterile hypodermic syringes for single use — Part 2: Syringes for use with power-driven syringe pumps. This document specifies requirements for sterile single-use hypodermic syringes of nominal capacity 1 ml and above, made of plastic materials and intended for use with power-driven syringe pumps. This document does not apply to syringes with auto-disable syringe features (ISO 7886-3 [2] ), syringes for use with insulin (ISO 8537 [3] ), single-use syringes made of glass, syringes prefilled with the injection by the manufacturer and syringes supplied with the injection as a kit for filling by a pharmacist. It does not address compatibility with injection fluids. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3696, Water for analytical laboratory use — Specification and test methods ISO 7886-1:2017, Sterile hypodermic syringes for single use — Part 1: Syringes for manual use ISO 80369-7, Small-bore connectors for liquids and gases in healthcare applications — Part 7: Connectors for intravascular or hypodermic applications ISO/IEC Guide 99, International vocabulary of metrology — Basic and general concepts and associated terms (VIM) 3Terms and definitions For the purposes of this document, the terms and definitions given in ISO 7886-1, ISO/IEC Guide 99 and the following apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: — ISO Online browsing platform: available at https:// www .iso .org/ obp — IEC Electropedia: available at http:// www .electropedia .org/ 3.1 parking position location in the barrel where the plunger stopper is positioned before the user opens the packaging 4 Nomenclature The requirements specified in ISO 7886-1:2017, Clause 4 apply. 5 General requirements The requirements specified in ISO 7886-1:2017, Clause 5 apply. 6 Limits for acidity or alkalinity The requirements specified in ISO 7886-1:2017, 6.2 apply. 7 Limits for extractable metals The requirements specified in ISO 7886-1:2017, 6.3 apply. 8 Lubricant The requirements specified in ISO 7886-1:2017, Clause 7 apply. 9 Tolerance on graduated capacity The requirements specified in ISO 7886-1:2017, Clause 8 apply. 10 Graduated scale The requirements specified in ISO 7886-1:2017, Clause 9 apply. 11 Syringe design Critical dimensions for the fit of the syringe in a syringe pump...

Download Address

  • Download